An equipment to test the stacking load carrying capacity of corrugated cartons.
Top to bottom compression strength of corrugated cartons is the most appropriate performance specification related to stack-ability characteristics and is the index of the overall quality of the carton.

Common Specs

  • Standard Model
  • Digital Electro – Pneumatic model.
  • Digital Model with Backlit LCD Display for easy readibility.
  • Direct Display of Load / Collapsing Force. No Calculations Required.
  • Auto-stop upon completion of Test.
  • Testing Principle : Constant Rate of Loading
  • With non-destructive testing facility for cartons at predetermined load.
  • User Selectable Test Units : Kgf / Lbf / N

INCLUDES : An Air Filter cum Regulator to ensure long working life to the machine.

 

Optional Item (generally suggested for Pharmaceutical Companies only) :

IQOQ / Validation Documentation Set.

Model # P1000D

Model # P1000D is a standalone model with 2 line, backlit, LCD display.

  • Capacity:                   1000 Kgf  (10,000 N)
  • Least Count :            1 Kgf.        (10 N)
  • Suitable for a Testing Range of :        100 – 900 Kgf             (1000 – 9,000N)
  • With auto-calibration facility at 100 Kgf

 

Small Size :  

Machine Platform Size : 600 x 600 mm                     (Approx)

Maximum Carton size of 550 x 550 x 550 mm can be accommodated.

           

Standard Size :

Machine Platform Size : 900 x 750 mm                     (Approx)

Maximum Carton size of 850 x 725 x 850 mm can be accommodated.

 

Large Size :

Machine Platform Size : 1000 x 1000 mm                  (Approx)

Maximum Carton size of 950 x 950 x 950 mm can be accommodated.

 

INCLUDES : An Air Filter cum Regulator to ensure long working life to the machine.

 

Utilities Required (To be supplied by the buyer) :

  • Power Supply : 110/230 Volts AC at 60/50 Hz. (Fluctuation Free Power required)
  • Compressed Air supply at 5 – 6 kg/cm2 (Rust, Dirt and Moisture Free Supply)
  • 100 Kg Cast Iron Weights (In any combination. Preferably, 20kg x 5 nos)

These weights are required for calibration at the time of installation and then every 6-months for routine calibrations.

 

Computerised Model (P1000DDX) also available

 

Optional Item (generally suggested for Pharmaceutical Companies only) :

IQOQ / Validation Documentation Set.

Model # P1000DDX

Model # P1000D is a PC Software driven machine which can also operate as a standalone model with 2 line, backlit, LCD display.

  • Capacity:                   1000 Kgf  (10,000 N)
  • Least Count :            1 Kgf.        (10 N)
  • Suitable for a Testing Range of :        100 – 900 Kgf             (1000 – 9,000N)
  • With auto-calibration facility at 100 Kgf

 

  • Fully Automatic Model with Computer Controlled operations.
  • Full Controls and Calibration function via computer.
  • Non-21CFR-Part-11 compliant software.
  • Test Report (with Load vs Time Graph) Printing facility.
  • Calibration Report Printing facility.
  • Facility to print on Pre-Printed or Blank Stationery.

( Includes Software and Linking Hardware. PC & Printer to be provided by you. )

 

Small Size :  

Machine Platform Size : 600 x 600 mm                     (Approx)

Maximum Carton size of 550 x 550 x 550 mm can be accommodated.

           

Standard Size :

Machine Platform Size : 900 x 750 mm                     (Approx)

Maximum Carton size of 850 x 725 x 850 mm can be accommodated.

Large Size :

Machine Platform Size : 1000 x 1000 mm                  (Approx)

Maximum Carton size of 950 x 950 x 950 mm can be accommodated.

 

INCLUDES : An Air Filter cum Regulator to ensure long working life to the machine.

 

Utilities Required (To be supplied by the buyer) :

  • Power Supply : 110/230 Volts AC at 60/50 Hz. (Fluctuation Free Power required)
  • Compressed Air supply at 5 – 6 kg/cm2 (Rust, Dirt and Moisture Free Supply)
  • 100 Kg Cast Iron Weights (In any combination. Preferably, 20kg x 5 nos)

These weights are required for calibration at the time of installation and then every 6-months for routine calibrations.

  • Desktop PC or Laptop PC
  1. Processor Type :   Pentium Core I3 or better.      (Preferably Core I5 or Higher)
  2. Memory :              2 GB RAM or better
  3. Space :                  50 GB free HDD space           (minimum)
  4. Monitor :               17” or larger Color Monitor with 1280 x 1024 resolution or better
  5. Operating System: Windows 7 Home Premium or higher (with latest updates & patches)
  6. Supporting Software :       Adobe Acrobat Reader                       (Latest Version).
  7. Microsoft Dot Net Framework           (Latest Version)
  8. Communication :  9-Pin (DB9) Serial Port (RS-232)     REQUIRED
  9. Printer :                 Laser or Inkjet Printer.            (No Dot-matrix support)

 

Optional Item (generally suggested for Pharmaceutical Companies only) :

IQOQ / Validation Documentation Set.

© Copyright Test Techno Consultants 2019. All rights reserved